Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 46
Filtrar
1.
Endosc Ultrasound ; 3(Suppl 1): S9, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26425538

RESUMO

OBJECTIVES: Endoscopic ultrasonography (EUS) and endobronchial ultrasound-fine-needle aspiration (EBUS-FNA), is an accurate technique for evaluation of mediastinal lymph nodes (MLN) and stadification of lung cancer. The aims of the study are to evaluate the feasibility and the efficacy of the combined technique compared with mediastinoscopy for the diagnosis of MLN. DESIGN AND METHODS: All patients with suspected malignant MLN and/or lung lesion identified by positron emission tomography-computed tomography underwent combined EUS-EBUS-FNA. The combined procedure was performed in outpatients under general anesthesia for EUS and sedation by intravenous midazolam for EBUS when performed separately, using linear-array echoendoscopes. The MLN were punctured during the EUS and EBUS-FNA procedures with a 22 gauge needle. RESULTS: Thirty-four patients underwent consecutively EUS and EBUS-FNA between September 2011 and November 2013 (8 women, 26 men, mean age of 65.9 year, range: 51-83). Combined EUS-EBUS-FNA was performed in a single time procedure in 26 patients (mean time 50 min) and in two different times in eight patients (mean delay 3 days). Twenty-five malignant and 9 inflammatory lesions were diagnosed. Mediastinoscopy was performed in nine patients and confirmed in eight patients the initial combined EUS-EBUS-FNA diagnosis. The diagnosis was obtained in 91.2% with EUS-FNA, 70.6% with EBUS-FNA and 97% when combined procedure was performed. The overall sensitivity, specificity, positive and negative predictive values of EUS-EBUS-FNA for diagnosing malignancy were 96.5%, 100%, 100% and 90% respectively. No complications related to the procedure were observed. CONCLUSION: Combined EUS-EBUS-FNA represents an accurate technique in the diagnosis of MLN, can be done in a single time procedure and has the advantage of being less invasive than mediastinoscopy.

2.
Acta Anaesthesiol Scand ; 56(1): 76-82, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22150409

RESUMO

BACKGROUND: Neuromuscular blocking agents have always shown wide inter-individual variability when it comes to their duration of action. This prevents clinicians from anticipating the evolution of the neuromuscular block for any given patient. With this study, we aimed to assess the nature of the relationships existing between different time course parameters used to describe paralysis onset and offset. METHODS: Sixty American Society of Anesthesiologists (ASA) score III-IV anaesthetised patients were randomised to receive a single equipotent dose (2ED95) of either rocuronium, mivacurium or atracurium. We used acceleromyography to monitor neuromuscular transmission. We described the relationships between the time-interval measurements of: onset, the first response (T1) reappearance, T1 25% of control, train-of-four ratio 0.25 and 0.75. Pearson correlation coefficients were calculated. RESULTS: We found no significant relationships between onset and any of the four parameters used to describe the offset. On the other hand, we showed strong and highly significant linear relationships between all the parameters describing the offset for each of the muscle relaxants studied (correlation coefficients ranging from 0.850 to 0.992). CONCLUSIONS: We evidenced strong linear correlations between the four offset time course parameters of spontaneous recovery after a single neuromuscular blocking agents (NMBAs) bolus. Such relationships open up new clinical perspectives concerning quantitative neuromuscular transmission monitoring: the scope of individual valuable anticipation of the patient's recovery.


Assuntos
Bloqueio Neuromuscular/normas , Idoso , Idoso de 80 Anos ou mais , Androstanóis , Período de Recuperação da Anestesia , Anestesia Geral , Atracúrio , Calibragem , Ponte de Artéria Coronária , Eletromiografia , Feminino , Humanos , Isoquinolinas , Nefropatias/complicações , Hepatopatias/complicações , Masculino , Pessoa de Meia-Idade , Mivacúrio , Monitorização Intraoperatória , Fármacos Neuromusculares não Despolarizantes , Rocurônio , Fatores de Tempo , Resultado do Tratamento
3.
Eur J Vasc Endovasc Surg ; 42(6): 766-74, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21945512

RESUMO

OBJECTIVES: To compare outcomes after carotid endarterectomy (CEA) with saphenous vein patch closure (SV), with cervical vein (external jugular and common facial) patch closure (CV). DESIGN: A total of 322 cases of CEA was achieved consecutively by using venous patch angioplasty. Propensity scores were calculated followed by a one-to-one basis case-matching. MATERIALS: This resulted into 90 SV and 90 CV matched cases. METHODS: The primary endpoint was the incidence of ipsilateral stroke and transient ischaemic attack at any time during follow-up. RESULTS: Ten-year freedom from stroke was 94.1% ± 3.5% for the SV group and 90.5% ± 4.2% for the CV group (log rank P = 0.230). Ten-year freedom from ipsilateral neurological events (stroke and transient ischaemic attack) was 93.5% ± 3.3% for SV group and 92.4% ± 3.0% for the CV group (log rank P = 0.403). Ten-year freedom from ≥75% stenosis/occlusion was 93.1 ± 4.8% for the SV group and 89.9 ± 6.0% for the CV group (log rank P = 0.481). CONCLUSIONS: CV is a good alternative to SV patching, particularly when the SV needs to be preserved for further use or is unsuitable.


Assuntos
Implante de Prótese Vascular , Endarterectomia das Carótidas/métodos , Veias/transplante , Idoso , Valva Aórtica/cirurgia , Estudos de Casos e Controles , Comorbidade , Ponte de Artéria Coronária , Feminino , Seguimentos , Implante de Prótese de Valva Cardíaca , Humanos , Ataque Isquêmico Transitório/etiologia , Ataque Isquêmico Transitório/mortalidade , Masculino , Pessoa de Meia-Idade , Exame Neurológico , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/mortalidade , Estudos Prospectivos , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/mortalidade
4.
Transplant Proc ; 41(2): 607-9, 2009 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19328937

RESUMO

OBJECTIVE: Basiliximab (BAS), an interleukin-2 monoclonal antibody, has shown promising results as induction therapy in liver and kidney transplantation. We compared the efficacy and patient tolerability of BAS and antithymocyte globulin (ATG) in lung transplantation (LTx). PATIENTS AND METHODS: The study included 37 patients in two groups (ATG and BAS, respectively). The indication for LTx was emphysema in 62.6% of patients in group 1 and 57.1% of patients in group 2. Mean (SD) patient characteristics compared in the two groups included age (52.0 [9.8] vs 54 [10.6] years), height (172.0 [10.1] vs 169 [7.55] cm), and weight (73.9 [15.3] vs 64.4 [14.2] kg) (P = .049). Induction therapy after LTx in the two groups was as follows: in 16 transplantation procedures (eight single and eight bilateral) performed between April 1998 and December 2002, ATG, 3 mg/kg/d for 3 days, was administered, and in 21 transplantation procedures (15 single and 6 bilateral) performed between January 2003 and July 2005, BAS, 20 mg on days 0 and 4, was given. Dosages of cyclosporine, azathioprine, and steroids for maintenance therapy were equivalent in the two groups. We retrospectively compared patient tolerability, occurrence of acute rejection or infection (from bacteria, cytomegalovirus [CMV], or Aspergillus), and outcomes between the two groups during 2 years of follow-up. RESULTS: No cytokine-mediated reaction was observed in either group; however, there was a difference in hematologic effects. On day 2, mean (SD) platelet count was significantly lower in the ATG group at 113,500 (56,400)/mm(3) vs 151,900 (57,300)/mm(3) (P = .046). Because of severe thrombocytopenia, three patients could not be given ATG on day 3. The overall incidence of aspergillosis (18.8% vs 19.0%) and CMV infection (31% vs 57%) was similar in the two groups. However, when the recipient was CMV-positive and the donor was CMV-negative, the there was a clear trend (33.3% vs 88.9%). The number of acute rejection episodes was similar (43.8% vs 52.4%). Survival increased by 20% in the BAS group (P = .03). CONCLUSION: In LTx, safety of BAS use is as good as or better than that of ATG, with no difference in acute rejection episodes or infections, with the possible exception of increased reactivation of CMV infection. Thus, BAS could be an alternative to ATG as induction therapy in LTx; however, further studies are necessary.


Assuntos
Anticorpos Monoclonais/uso terapêutico , Soro Antilinfocitário/uso terapêutico , Imunossupressores/uso terapêutico , Transplante de Pulmão/imunologia , Proteínas Recombinantes de Fusão/uso terapêutico , Adulto , Anticorpos Monoclonais/efeitos adversos , Soro Antilinfocitário/efeitos adversos , Aspergilose/tratamento farmacológico , Aspergilose/epidemiologia , Basiliximab , Infecções por Citomegalovirus/tratamento farmacológico , Infecções por Citomegalovirus/epidemiologia , Quimioterapia Combinada , Tolerância a Medicamentos , Feminino , Rejeição de Enxerto/epidemiologia , Humanos , Pneumopatias/classificação , Pneumopatias/cirurgia , Transplante de Pulmão/mortalidade , Masculino , Metilprednisolona/uso terapêutico , Pessoa de Meia-Idade , Proteínas Recombinantes de Fusão/efeitos adversos , Estudos Retrospectivos , Segurança , Análise de Sobrevida , Sobreviventes
6.
Arch Pediatr ; 13(9): 1209-14, 2006 Sep.
Artigo em Francês | MEDLINE | ID: mdl-16716576

RESUMO

OBJECTIVES: To describe the necrotizing pneumonia in children, a severe affection which prevalence seems to increase; to review literature. PATIENTS AND METHODS: We report 4 cases of necrotizing pneumonia: symptoms, agents, diagnostic tools, treatment and long term evolution. RESULTS: In 2 cases, pneumatoceles could be seen at chest X-ray. Two patients presented a deficiency of anti-pneumococcal antibodies. Three needed insertion of a pleural chest tube of whom 1 had a resection of a small piece of necrotic lung. Duration of hospitalisation is longer than in uncomplicated pneumonias. CONCLUSION: Necrotizing pneumonia is a severe affection. Diagnosis has to be made by lung CT. Long term evolution is excellent in pediatric population with serious management at hospital.


Assuntos
Pneumonia Bacteriana/patologia , Adolescente , Antibacterianos/uso terapêutico , Criança , Pré-Escolar , Drenagem , Feminino , Humanos , Tempo de Internação , Masculino , Necrose , Pneumonia Bacteriana/microbiologia , Pneumonia Bacteriana/terapia
7.
Rev Med Liege ; 61(1): 16-22, 2006 Jan.
Artigo em Francês | MEDLINE | ID: mdl-16491543

RESUMO

Based on an increased prevalence of empyema in children,we reviewed the literature on the diagnosis and management of this affection. A retrospective study of 11 children admitted to our hospital in 2003 shows a prolonged hospitalisation (median 18 days) even with adequate treatment. Based on our experience and data from the literature, we propose a management algorithm to allow treatment of children admitted ith pleural effusion.


Assuntos
Algoritmos , Empiema Pleural/complicações , Derrame Pleural/terapia , Fatores Etários , Criança , Hospitalização , Humanos , Planejamento de Assistência ao Paciente
8.
Acta Chir Belg ; 101(3): 130-4, 2001.
Artigo em Inglês | MEDLINE | ID: mdl-11501388

RESUMO

OBJECTIVE: The aim of this study was to evaluate initial results in beating heart coronary artery bypass grafting performed on patients with multivessel disease, using suction-based tissue stabilizers. METHODS: Forty patients (mean age 65.5 years, range 39-83) underwent beating heart coronary bypass by median sternotomy, with the use of the Octopus 1 (n = 27) and Octopus 2 (n = 13) devices. Twenty patients had unstable angina, four had pulmonary oedema, and four required preoperative intra-aortic balloon counterpulsation. Five interventions were repeat procedures. Mean ejection fraction was 54.4%(range 20-82%). Eighteen patients had triple-vessel disease, 18 patients had double-vessel disease and > 50% left main stem stenosis was present in six patients (isolated or in association). The average number of distal anastomoses was 2.5 (range 1-5, total 101). A mean of 1.5 (range 1-3) anastomoses was achieved with arterial grafts (45 mammary and 12 gastroepiploic arteries). RESULTS: Immediate graft patency was evaluated by Doppler flowmeter and five anastomoses were successfully corrected, based on an occlusion pattern. The perioperative myocardial infarction rate was zero. Transient episodes of supraventricular arrhythmias were detected in 19 patients. The administration of dobutamine at an inotropic concentration > 5 gamma-1 kg-1 min-1 was required in one patient. There were two in-hospital deaths (one non-cardiac-related). Overall survival and cardiac event-free rate at 20 months were 92.4% +/- 4.2% and 81.8% +/- 11.6%, respectively. CONCLUSIONS: Satisfactory results can be achieved in multivessel disease high-risk patients with beating heart coronary bypass surgery.


Assuntos
Ponte de Artéria Coronária/instrumentação , Doença das Coronárias/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Transfusão de Sangue , Ponte Cardiopulmonar , Ponte de Artéria Coronária/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Fatores de Risco , Grau de Desobstrução Vascular
9.
Cardiovasc Surg ; 9(5): 463-8, 2001 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-11489650

RESUMO

PURPOSE: This retrospective study evaluates the long-term clinical outcome and the survival of 600 consecutive carotid endarterectomies performed with a temporary shunt. All arteriotomies were closed by vein patch angioplasty. MATERIALS AND METHODS: Between November 1989 and November 1998, 600 isolated carotid endarterectomies (CEA) were performed in 540 patients by a uniform surgical technique at the University Clinic of Mont-Godinne. An intraluminal shunt and patch closure were systematically used. The mean age was 68 yr (ranging from 41 to 91 yr), 400 patients were men. The risk factors included hypertension in 73%, smoking history in 60%, coronary artery disease in 51% and hyperlipidemia in 35%. The indications were asymptomatic stenosis in 47%, transient ischemic attack in 40%, vertebrobasilar symptoms in 7% and stroke in 6%. EARLY RESULTS: The combined 30-day stroke and death rate was 0.9%. There were four deaths. The stroke and TIAs rates were 0.2% and 1.5% respectively. The incidence of early carotid occlusion was 0.5%. Cranial or cervical nerve dysfunction was identified in 6.3%. LATE RESULTS: The median follow-up was 49 months with a range of 2-124 months. Cumulative survival rates at 5 and 10 yr were 92+/-1% and 89+/-2% respectively. Thirty-two patients died during long-term follow-up; the death was stroke-related in only three patients. CONCLUSION: Carotid endarterectomy using an intraluminal shunt and vein patch closure is a safe and effective procedure associated with low morbidity and mortality rates at short and long-term follow-up.


Assuntos
Angioplastia/mortalidade , Endarterectomia das Carótidas/mortalidade , Técnicas de Patch-Clamp/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Estenose das Carótidas/complicações , Estenose das Carótidas/diagnóstico por imagem , Estenose das Carótidas/cirurgia , Feminino , Seguimentos , Humanos , Ataque Isquêmico Transitório/epidemiologia , Ataque Isquêmico Transitório/etiologia , Masculino , Pessoa de Meia-Idade , Assistência Perioperatória , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Fatores de Risco , Acidente Vascular Cerebral/etiologia , Análise de Sobrevida , Tempo , Resultado do Tratamento , Ultrassonografia Doppler Dupla
10.
Ann Thorac Surg ; 71(3): 986-8, 2001 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-11269486

RESUMO

BACKGROUND: A limiting factor in performing video-assisted thoracic surgery for resection of peripheral solitary pulmonary nodules has been the recognition of the lesion visually. This study reports our clinical experience of injecting a small metallic marker under computed tomographic scan guidance before the operation, allowing localization of the lesion. METHODS: A series of 14 patients underwent video-assisted thoracic surgery for removal of 15 pulmonary nodules situated in the outer third of the lung. Before operation, a radiopaque microcoil was injected just behind the lesion and then used to locate, under fluoroscopy, the area to be resected during thoracoscopy. The technique was evaluated for accuracy, reliability, and ease of use. RESULTS: Microcoil labeling of peripheral pulmonary nodules allowed in every case a complete resection and a histologic identification of the lesion. It is more stable and accurate than methylene blue dye marking, and it is as easy to perform as computed tomographic scan-guided biopsy. The incidence of complication was small in spite of our inexperience with the technique. CONCLUSIONS: Our experience with microcoil injection shows that it provides consistent and highly accurate marking of pulmonary nodules for video-assisted thoracic surgery, allowing secure resection with a safe margin.


Assuntos
Nódulo Pulmonar Solitário/diagnóstico por imagem , Nódulo Pulmonar Solitário/cirurgia , Cirurgia Torácica Vídeoassistida , Tomografia Computadorizada por Raios X , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Cuidados Pré-Operatórios , Cirurgia Torácica Vídeoassistida/métodos
11.
Ann Thorac Surg ; 70(1): 151-6, 2000 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-10921700

RESUMO

BACKGROUND: Supraventricular tachyarrhythmia (SVT) commonly occurs shortly after coronary artery bypass grafting (CABG), but ventricular arrhythmias are less documented. METHODS: On the 1st postoperative day, 206 consecutive eligible patients were prospectively randomized to a sotalol group (80 mg b.i.d.; n = 103) or a control group without beta-blockade or antiarrhythmic drugs (n = 103). RESULTS: The SVT incidence (predominantly atrial fibrillation) accounted for 16% in the sotalol group versus 48% (p < 0.00001). Multivariate analysis showed that sotalol reduced the SVT incidence (p < 0.00001, odds ratio, 0.20; 95% confidence interval, 0.09 to 0.42), whereas a lower preoperative left ventricular ejection fraction (p = 0.019) and older age (p = 0.031) were independent risk factors of SVT occurrence. The Holter electrocardiographic analysis (24 hours) demonstrated that sotalol (32 versus 92; p = 0.031) decreased the median number of ventricular events, mostly isolated premature ventricular beats. Neither ventricular proarrhythmia effect nor "torsades de pointes" were detected. Despite strict hemodynamic-based selection, sotalol had to be discontinued in 8 patients (7.8%), for reasons related to asthma in 3 or cardiac reasons in 5. CONCLUSIONS: Oral low-dose sotalol provided considerable and reliable protection in selected nondepressed cardiac function patients, reducing the occurrence of both supraventricular and ventricular arrhythmias after CABG.


Assuntos
Antiarrítmicos/administração & dosagem , Ponte de Artéria Coronária/efeitos adversos , Sotalol/administração & dosagem , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/prevenção & controle , Administração Oral , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Estudos Prospectivos , Fatores de Risco , Taquicardia Ventricular/epidemiologia
12.
J Am Coll Cardiol ; 35(6): 1411-5, 2000 May.
Artigo em Inglês | MEDLINE | ID: mdl-10807440

RESUMO

OBJECTIVES: The present study was aimed to evaluate the efficacy of a specific algorithm with continuous atrial dynamic overdrive pacing to prevent atrial fibrillation (AF) after coronary artery bypass graft (CABG) surgery. BACKGROUND: Atrial fibrillation occurs in 30% to 40% of patients after cardiac surgery with a peak incidence on the second day. It still represents a challenge for postoperative prevention and treatment and may have medical and cost implications. METHODS: Ninety-six consecutive patients undergoing CABG for severe coronary artery disease and in sinus rhythm without antiarrhythmic therapy on the second postoperative day were randomized to have or not 24 h of atrial pacing through temporary epicardial wires using a permanent dynamic overdrive algorithm. Holter ECGs recorded the same day in both groups were analyzed to detect AF occurrence. RESULTS: No difference was observed in baseline data between the two study groups, particularly for age, male gender, history of AF, ventricular function, severity of coronary artery disease, preoperative beta-adrenergic blocking agent therapy or P-wave duration. The incidence of AF was significantly lower (p = 0.036) in the paced group (10%) compared with control subjects (27%). Multivariate analysis showed AF incidence to increase with age (p = 0.051) but not in patients with pacing (p = 0.078). It decreased with a better left ventricular ejection fraction only in conjunction with atrial pacing (p = 0.018). CONCLUSIONS: We conclude that continuous atrial pacing with an algorithm for dynamic overdrive reduces significantly incidence of AF the second day after CABG surgery, particularly in patients with preserved left ventricular function.


Assuntos
Fibrilação Atrial/prevenção & controle , Estimulação Cardíaca Artificial , Ponte de Artéria Coronária , Complicações Pós-Operatórias/prevenção & controle , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Eletrocardiografia Ambulatorial , Feminino , Hemodinâmica/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento , Função Ventricular Esquerda/fisiologia
14.
J Am Soc Echocardiogr ; 12(10): 827-33, 1999 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-10511651

RESUMO

Doppler-derived left ventricular (LV) rate of pressure rise (Dop LV DeltaP/Deltat) is described as an index of LV performance in the presence of mitral regurgitation (MR). This study was designed to define more accurately the accuracy of the method in the presence of severe MR. Ten pigs were anesthetized and monitored. MR was gradually created. At each grade of MR, preload was manipulated with the intent of modifying LV end-diastolic area value within a range of +/-20%. Concurrently, the mean left atrial pressure (LAP) was recorded, MR was quantified by the mitral to aortic velocity-time integral ratio (mitroaortic VTI ratio), Dop LV DeltaP/Deltat was calculated, and peak LV dP/dt was derived from LV catheterism data. During the procedure Dop LV DeltaP/Deltat gradually underestimated peak LV dP/dt. This difference was correlated to the mean LAP (P < 10(-5)) and mitroaortic VTI ratio (P < 10(-5)) and became clinically significant when the mean LAP was superior to 21 mm Hg.


Assuntos
Ecocardiografia Doppler em Cores , Insuficiência da Valva Mitral/fisiopatologia , Disfunção Ventricular Esquerda/fisiopatologia , Pressão Ventricular , Animais , Velocidade do Fluxo Sanguíneo , Diástole/fisiologia , Insuficiência da Valva Mitral/diagnóstico por imagem , Análise de Regressão , Suínos , Disfunção Ventricular Esquerda/diagnóstico por imagem
15.
Heart ; 82(3): 336-42, 1999 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-10455085

RESUMO

OBJECTIVE: To compare the mechanisms by which arterial and venous grafts increase their flow during pacing induced tachycardia, early and later after coronary bypass surgery. DESIGN: 43 grafts (13 epigastric artery, 15 mammary artery, 15 saphenous vein) evaluated early (9 (3) days (mean (SD)) after bypass surgery were compared with 41 other grafts (15 epigastric, 11 mammary, 15 saphenous vein) evaluated later after surgery (mean 23 months, range 6 to 168 months) by quantitative angiography and intravascular Doppler velocity analysis during atrial pacing. Controls were 17 normal coronary arteries. RESULTS: Baseline graft flow tended to be lower later after surgery than early (41 (16) v 45 (21) ml/min, NS). Blood flow increased during pacing by 30 (16)% early after surgery, less than later after surgery (+46 (18)%, p < 0.001) and less than in normal coronary arteries (+54 (27)%, p < 0.001 v early grafts; NS v late grafts). There was no difference between venous and arterial grafts. No significant vasodilatation was observed during pacing early after surgery in arterial and venous grafts. Later after surgery, significant vasodilatation was observed only in arterial grafts (mammary and epigastric grafts), from 2.41 (0.37) to 2.53 (0. 41) mm (+5.1% v basal, p < 0.001). Early after surgery and in venous grafts later after surgery, the increase in flow was entirely due to an increase in velocity. In later arterial grafts, the relative contribution of the increase in velocity to the increase in flow during pacing was lower in arterial grafts (70 (22)%) than in venous grafts (102 (11)%, p < 0.001) and similar to normal coronary arteries (68 (28)%). CONCLUSIONS: Early and later after surgery, arterial grafts and venous grafts both increase their flow similarly during pacing. Early arterial grafts and venous grafts increase their flow only through an increase in velocity. Later after surgery, arterial grafts act as more physiological conduits and increase their flow in the same way as normal coronary arteries, through an increase in velocity and calibre mediated by the endothelium.


Assuntos
Adaptação Fisiológica , Ponte de Artéria Coronária , Circulação Coronária , Idoso , Velocidade do Fluxo Sanguíneo , Estimulação Cardíaca Artificial , Endotélio Vascular/fisiopatologia , Artérias Epigástricas/transplante , Feminino , Seguimentos , Hemodinâmica , Humanos , Dinitrato de Isossorbida , Masculino , Artéria Torácica Interna/transplante , Pessoa de Meia-Idade , Período Pós-Operatório , Veia Safena/transplante , Vasodilatação , Vasodilatadores
16.
J Thorac Cardiovasc Surg ; 118(2): 330-8, 1999 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-10425007

RESUMO

OBJECTIVE: Blood flow characteristics of right gastroepiploic artery and saphenous vein conduits were compared during bypass surgery. METHODS: This study is based on a consecutive series of 97 patients undergoing a bypass graft to the right coronary artery, posterior descending artery, or posterolateral branch using either a pediculated right gastroepiploic artery (n = 52) or a saphenous vein (n = 45) bypass graft. Flows and velocity profiles were measured with an 8-MHz pulsed-wave Doppler ultrasound flowmeter. Thorough flow measurements were made (1) after cessation of cardiopulmonary bypass and (2) before chest closure. RESULTS: At the end of cardiopulmonary bypass, flow in the right gastroepiploic artery (59. 0 +/- 6.7 mL/min) did not differ (P =.08) from flow in the saphenous vein (46.1 +/- 2.7 mL/min). Mean trace velocity was 11.9 +/- 0.7 cm/s in the right gastroepiploic artery and 11.6 +/- 0.8 cm/s in the saphenous vein (P =.80), but peak systolic velocity was 29.4 +/- 1.2 cm/s for the right gastroepiploic artery and 23.1 +/- 1.3 cm/s for the saphenous vein (P <.001). Likewise, before chest closure, flow was 57.1 +/- 4.7 mL/min in the right gastroepiploic artery and 46.5 +/- 4.0 mL/min in the saphenous vein (P =.10), mean velocity was 12. 9 +/- 0.7 and 11.6 +/- 0.8 cm/s, respectively (P = .22), and systolic peak velocity was 30.0 +/- 1.2 and 22.3 +/- 1.2 cm/s, respectively (P < .001). CONCLUSIONS: There were no flow differences between right gastroepiploic artery and saphenous vein grafts implanted into the same coronary bed in comparable groups of patients. Waveform shape of the right gastroepiploic artery grafts was characterized by a wider spectral dispersion resulting in a higher maximal frequency.


Assuntos
Vasos Coronários/cirurgia , Hemodinâmica/fisiologia , Monitorização Intraoperatória , Veia Safena/transplante , Artéria Esplênica/transplante , Idoso , Implante de Prótese Vascular , Ponte Cardiopulmonar , Doença das Coronárias/cirurgia , Vasos Coronários/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Intraoperatória/métodos , Reologia , Veia Safena/diagnóstico por imagem , Veia Safena/fisiologia , Artéria Esplênica/diagnóstico por imagem , Artéria Esplênica/fisiologia , Estômago/irrigação sanguínea , Ultrassonografia Doppler de Pulso
17.
Eur J Cardiothorac Surg ; 15(3): 240-6, 1999 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-10333016

RESUMO

OBJECTIVE: The patency of a pedicled right gastroepiploic artery (RGEA) graft can be compromised by intraoperative twists, kinks or spasms. Therefore, a systematic flow assessment was made in RGEA grafts and was compared with similar measurements made in other types of bypass conduits. METHODS: Intraoperative pulsed Doppler flowmeter measurements obtained in a series of 556 consecutive patients undergoing at least one coronary bypass grafting onto the right coronary system were studied. Eighty-five RGEA grafts were compared with 1427 bypass grafts implanted in the same group of patients and consisted of the following conduits: 442 left internal mammary (LIMA), 149 right internal mammary (RIMA), 831 greater saphenous vein (GSV) and five inferior epigastric (EPIG) grafts. Sequential grafts were excluded from the analysis. RESULTS: Flow measurements and Doppler waveforms were abnormal and required graft repositioning, and the addition of a distal graft or intragraft papaverine injection (only in GSVs) in 29 cases (2.0% of all grafts). These graft corrections were necessary in 5.9% RGEAs, 3.4% LIMAs, 2.0% RIMAs, and 0.7% GSVs (P < 0.001). The relative risk for graft correction was eight times higher for RGEAs than for GSVs (P = 0.002). Flow increased from 8 +/- 2 to 54 +/- 5 ml/min (P < 0.0001). Flow data were significantly influenced by the type of run-off bed (P < 0.001), the measurements obtained in grafts implanted onto the right coronary artery and the left anterior descending artery being superior. Flows in RGEAs, however, were comparable with values obtained in other grafts implanted onto the same recipient coronary artery. CONCLUSIONS: A significantly higher incidence of graft malpositioning caused inadequate flows in RGEAs. However, normal flow values could be restored simply by assigning a better graft orientation under pulsed Doppler flowmeter control. Overall flow capacity of the RGEA did not differ from values obtained in other arterial and venous grafts implanted onto the same recipient arteries.


Assuntos
Ponte de Artéria Coronária/métodos , Ecocardiografia Doppler de Pulso , Estômago/irrigação sanguínea , Grau de Desobstrução Vascular , Idoso , Artérias/transplante , Doença das Coronárias/diagnóstico por imagem , Doença das Coronárias/fisiopatologia , Doença das Coronárias/cirurgia , Feminino , Humanos , Período Intraoperatório , Masculino , Pessoa de Meia-Idade , Fluxo Sanguíneo Regional , Resultado do Tratamento
18.
Ann Thorac Surg ; 66(4): 1282-7; discussion 1288, 1998 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-9800821

RESUMO

BACKGROUND: This study was designed to assess the value of hemodynamic measurements taken intraoperatively in predicting midterm patency of coronary bypass grafts. METHODS: A pulsed Doppler flowmeter was routinely used during operation to determine the hemodynamic parameters of coronary bypass grafts. During a 7-year period, 85 patients underwent angiographic evaluation. As a result, a thorough hemodynamic assessment of 214 grafts (89 arterial and 125 venous) at initial operation was available for analysis. RESULTS: The overall patency rate was 88.3%. The mean flow measured intraoperatively in 168 intact grafts was 60+/-3 mL/min (range, 9 to 230 mL/min), and the resistance was 1.8+/-0.1 peripheral resistance units (range, 0.3 to 9.0 peripheral resistance units). The mean flow was 36+/-5 mL/min (range, 2 to 107 mL/min), and the resistance was 5.9+/-2.0 peripheral resistance units (range, 0.6 to 46.0 peripheral resistance units) in 25 grafts found occluded at angiographic evaluation. Multivariate analysis identified three independent variables associated with a reduced patency rate: increased resistance as measured in the graft (p = 0.012), increasing interval of control angiography (p = 0.006), and preoperative cardiogenic shock (p = 0.040). CONCLUSIONS: The prognosis for midterm patency of aortocoronary bypass grafts depends on the intraoperative hemodynamic status.


Assuntos
Ponte de Artéria Coronária , Circulação Coronária/fisiologia , Oclusão de Enxerto Vascular/epidemiologia , Velocidade do Fluxo Sanguíneo/fisiologia , Angiografia Coronária , Feminino , Oclusão de Enxerto Vascular/diagnóstico , Humanos , Cuidados Intraoperatórios , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Ultrassonografia Doppler , Grau de Desobstrução Vascular/fisiologia
19.
J Am Soc Echocardiogr ; 11(5): 403-8, 1998 May.
Artigo em Inglês | MEDLINE | ID: mdl-9619610

RESUMO

A noninvasive method to assess left internal mammary artery (LIMA) patency and function would be useful because this vessel is frequently used for revascularization of the left anterior descending coronary artery. The purpose of this study was to assess the feasibility of measuring changes in LIMA velocities by transcutaneous Doppler during dipyridamole-induced vasodilation. Twenty-five patients with a LIMA graft anastomosed to the left anterior descending coronary artery were studied at least 1 month after surgery by the use of a 5 MHz transducer placed in the left supraclavicular fossa. Doppler velocity parameters were measured at baseline and after intravenous administration of dipyridamole. Dipyridamole increased mean velocity by 127% +/- 54% (p < 0.001), systolodiastolic velocity time integral by 89% +/- 31% (p < 0.001), and diastolic-to-systolic peak velocity ratio from 0.7 +/- 0.3 to 1.2 +/- 0.4 (p < 0.001). The dipyridamole-to-baseline mean velocity ratio was 2.3 +/- 0.5. We conclude that it is possible to measure dipyridamole-induced changes in LIMA flow velocities and thus obtain an index of LIMA blood velocity reserve by transcutaneous Doppler echocardiography.


Assuntos
Ecocardiografia Doppler/métodos , Oclusão de Enxerto Vascular/diagnóstico por imagem , Anastomose de Artéria Torácica Interna-Coronária , Adulto , Idoso , Velocidade do Fluxo Sanguíneo/efeitos dos fármacos , Velocidade do Fluxo Sanguíneo/fisiologia , Circulação Coronária/fisiologia , Dipiridamol , Estudos de Viabilidade , Feminino , Oclusão de Enxerto Vascular/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Grau de Desobstrução Vascular/fisiologia , Vasodilatadores
20.
Cardiovasc Surg ; 6(2): 126-32, 1998 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-9610824

RESUMO

BACKGROUND: The objective of this study was to analyse the impact of acute surgery for native aortic valve endocarditis and its influence on the long-term prognosis after surgery. METHODS: A total of 161 patients underwent aortic valve replacement for native active aortic valve endocarditis (NAAVE) during a 29-year period, from 1967 to 1995 (age range: 10 to 72 years; mean 48 +/- 12). The main indication for surgery was progressive congestive heart failure (76%). Other indications were untreatable sepsis (27%), peripheral or central emboli (12%) and, from 1978, echocardiographic evidence of friable, pedunculated vegetations (3%). Streptococcal and staphylococcal infections predominated. Concomitant procedures were performed in 27% of the patients, including mitral and tricuspid valve surgery and coronary bypass procedures. RESULTS: Operative mortality was 8% in the majority of cases caused by heart failure or multi-organ failure. Multivariate logistic regression analysis identified NYHA class IV to be an independent predictor for postoperative death. Long-term survival for discharged patients was 75% at 10 years and 58% at 15 years, with a mortality rate of 3.6%/patient/year. Cox regression analysis identified the year of operation, trivalvular endocarditis and staphylococcal infection as independent predictors of survival. At 10 and 15 years after aortic valve replacement, 91% and 84% of the patients, respectively, were free of recurrent endocarditis. The presence of an abscess cavity at first operation was found to be predictive of recurrent endocarditis. CONCLUSIONS: Valve replacement for NAAVE offers a good chance for a cure and satisfactory long-term survival. Improvements in pre- and per-operative management of the very ill patient, and the use of allograft valves are likely to further improve long-term results. Finally, the presence of staphylococcal endocarditis requires long-term postoperative antibiotic therapy.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Endocardite Bacteriana/complicações , Implante de Prótese de Valva Cardíaca/mortalidade , Infecções Estafilocócicas/complicações , Infecções Estreptocócicas/complicações , Adolescente , Adulto , Idoso , Valva Aórtica , Insuficiência da Valva Aórtica/etiologia , Bélgica/epidemiologia , Criança , Endocardite Bacteriana/microbiologia , Feminino , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/cirurgia , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Fatores de Risco , Infecções Estafilocócicas/diagnóstico , Infecções Estreptocócicas/diagnóstico , Taxa de Sobrevida
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...